3.3.4.20 DIAG8160 : "PERC Battery <PERC Controller Location> - incorrect status =
<80000000000000??>\n<Error Reason>."
When event is generated, message will have the following substitutions:
<PERC Controller Location> = "0"
<80000000000000??> = "8000000000000000"
<Error Reason> = "Battery missing or disconnected"
3.3.4.21 DIAG8166 : "OS - Suspect corrupt MBR, verify MBR with Anti-Virus Application."
3.3.5 Subcategory= Storage Enclosr [MessageID prefix =ENC]
3.3.5.1 ENC1 : "<Enclosure Management Module Name> was inserted."
When event is generated, message will have the following substitutions:
<Enclosure Management Module Name> = "EMM 0 in Enclosure 0 on Connector 1 of RAID Controller
in Slot 2"
3.3.5.2 ENC2 : "<Enclosure Management Module Name> was removed.."
When event is generated, message will have the following substitutions:
<Enclosure Management Module Name> = "EMM 0 in Enclosure 0 on Connector 1 of RAID Controller
in Slot 2"
3.3.5.3 ENC3 : "<Enclosure Name> is shutdown."
When event is generated, message will have the following substitutions:
<Enclosure Name> = "Enclosure 0 on Connector 0 of RAID Controller in Slot 5"
3.3.5.4 ENC4 : "<Enclosure Name> firmware mismatch."
When event is generated, message will have the following substitutions:
<Enclosure Name> = "Enclosure 0 on Connector 0 of RAID Controller in Slot 5"
3.3.5.5 ENC5 : "Redundancy on <Enclosure Name> is degraded"
When event is generated, message will have the following substitutions:
<Enclosure Name> = "Enclosure 0 on Connector 0 of RAID Controller in Slot 5"
3.3.5.6 ENC6 : "Communication timeout on <Enclosure Name>."
When event is generated, message will have the following substitutions:
<Enclosure Name> = "Enclosure 0 on Connector 0 of RAID Controller in Slot 5"
3.3.5.7 ENC7 : "The <Enclosure Name> alarm was enabled."
When event is generated, message will have the following substitutions:
<Enclosure Name> = "Enclosure 0 on Connector 0 of RAID Controller in Slot 5"