<errors>"
When event is generated, message will have the following substitutions:
<number of servers> = ""
3.1.24 Subcategory= Temperature [MessageID prefix =TMP]
3.1.24.1 TMP8500 : "I/O Module <iom slot name> temperature exceeded operating range."
When event is generated, message will have the following substitutions:
<iom slot name> = ""
3.1.24.2 TMP8501 : "Unable to read planar board temperature sensors. The cooling has been
increased to safeguard the system."
3.1.24.3 TMP8502 : "Able to read planar board temperature sensors. Cooling set for normal
chassis operation."
3.1.25 Subcategory= User Tracking [MessageID prefix =USR]
3.1.25.1 USR0002 : "<username> login from <ip_address>"
When event is generated, message will have the following substitutions:
<username> = "root"
<ip_address> = "192.168.1.1"
3.1.25.2 USR0005 : "Login failed from <username>: <ip_address>"
When event is generated, message will have the following substitutions:
<username> = "root"
<ip_address> = "192.168.1.1"
3.1.25.3 USR0007 : "<username> closing session from <ip_address>"
When event is generated, message will have the following substitutions:
<username> = "root"
<ip_address> = "192.168.1.1"